| Success
Stories
"While reviewing the
Alarms Log in our TNCS installation, I noticed that our narrow
cast optical transmitters were intermittently resetting. I
checked the video reception which did not appear to be degraded
and we were not receiving any customer complaints. However, our
system will begin offering telephony services in the near future
and if this resetting phenomena is not corrected, telephone
calls will be dropped each time the laser resets. Firm ware in
the transmitters was updated to correct the problem. We would
not have been aware of the potential problem without the
visibility TNCS provides."
"During a recent training
class we had several client computers connected to the active
TNCS installation. This is a relatively large installation with
a headend and 16 hub sites. All of a sudden we began getting
multiple alarms from one optical amplifier and many of the low
frequency receivers in several hub sites. Within less than 20
seconds we were able to identify the failed optical amplifier.
Armed with this information, two technicians were able to
replace the optical amplifier in less than seven minutes.
Without TNCS we would not have even known there was a problem in
seven minutes."
|